Spc-407k (cooling capacity 2500W)
 407-1.jpg        
 407-2.jpg        
 407-3.jpg        
 407-4.jpg        
 407-5.jpg        
Spc-407k (cooling capacity 2500W)
Function introduction
1. Adopt large brand Panasonic rotary closed compressor, stable performance and low failure rate
2. The integrated hydrophilic membrane internal thread, copper tube two row evaporator, three row condenser, more energy saving, less condensate
3. Aluminum centrifugal blade, strong wind, uniform airflow, low noise
4. All sheet metal structure, more durable, easy to carry, compact and flexible, easy to use, move as you please
5. Energy saving, no installation, plug and play
6. The two cold air outlets can automatically swing air at 75 degrees, which is suitable for cooling of 3-5 posts
7. The concentrated heat removal of flexible hose has less impact on the surrounding environment
8. It can be connected with internal water pipe of dehumidifier, and it can also store water scientifically
 407-1.jpg 407-2.jpg 407-3.jpg  407-4.jpg 407-5.jpg        
National 24-hour service hotline: 400-960-2220
Case center    
Product parameters
model SPC-407K
Power Supply Single phase 220 V / 50 Hz
Cooling capacity kw two point five
Cooling capacity BTU eight thousand and five hundred
Running current (a) four point six
Power consumption (kw) one point zero one
Water tank capacity (L) five
Air volume (m3 / h) three hundred and fifty
Automatic wind swing yes
Body size (mm) W400 D430 H820
Package size (mm) W465 D520 H1000
Gross weight (kg) forty-four
Net weight (kg) forty
Operating environment 25~45℃
Product features
 pro-detail1.png        
01 Panasonic compressor
Using Panasonic small rotary closed compressor, hydrophilic aluminum foil heat exchanger and internal thread copper tube, the refrigeration speed is faster, the efficiency is higher, and the energy saving is more silent.
 201872415455394.jpg    
       
02 unique drainage design
The design of the water tank is of pull-out type. It is more convenient to collect and pour water, and the external drainage pipe can also be selected.
 pd-2.png        
03 integrated design
Integrated design, standard plug, no need to install, power on. Convenient and fast.
 2018724151128592.jpg        
04 dust proof design
The unique dust control panel can reduce the harm of workshop dust and foreign matters to the machine.
 201872415185835.jpg        
05 75 ° automatic swing
The air outlet can automatically swing air at 75 ° and is suitable for cooling of 3-5 posts.
 2018724153843260.jpg        
06 external heat pipe
External heat pipe can be connected to realize the overall cooling of small space.
 pd-4.png        
07 high quality motor
Adopt all copper high quality motor, longer service life and lower noise.
 20181514831808.jpg        
08 dust screen
Equipped with filter screen to prevent the invasion of greasy dust.
 201815145337871.jpg        
09 all blade centrifugal aluminum
All aluminum centrifugal blades are used to make the air volume stronger and more uniform.
 2018724145447216.jpg        
10 design of hot and cold air separation
The cold and hot air separation technology can reduce the loss of cooling capacity, avoid the invasion of hot air, and greatly improve the efficiency of the machine.
 2018724143313140.jpg        
Random swing and precise positioning of 11 cold air duct
The cold air duct can be bent and rotated at large angle.
 201872415031230.jpg        
Design of 12 universal wheel
All machines are designed with universal wheel, which is convenient to move to any corner of space for use.     
 2018724152212623.jpg    
Application description
 0328153805.png    
Applicable place of mobile air conditioner:
1. As a post air conditioner, cooling is carried out for the staff in high temperature working environment.
2. Reduce the temperature of injection molding machine, communication equipment, machine tool distribution box and other mechanical equipment, so as to improve the working efficiency and prolong the service life of the equipment.
3. It is necessary to cool down the working place which needs ventilation and cannot be closed, such as outdoor exhibition hall, hotel backyard, construction site and other places where it is difficult to install air conditioning in the overall space, so as to provide staff with a cool and comfortable working environment
For outdoor sports, such as barbecue, etc
5. Cool down the products produced in the equipment to improve the product quality
Precautions for use of mobile air conditioner:
1. When there is adhesion or dust on the body surface of mobile air conditioner, it can be cleaned with soapy water to avoid using gasoline, petroleum essence, solvent, etc., to avoid paint dropping or discoloration.
2. The filter screen of the mobile air conditioner should be cleaned regularly (about once every 2 weeks) to maintain the dehumidification and dust removal efficiency and service life of the mobile air conditioner, and to avoid bacterial breeding.
3. When cleaning the upper part and lower part of the heat exchanger with hot water, it is necessary to clean the upper part and lower part of the heat exchanger with water.
4. When the mobile air conditioner is not used for a long time, please pull out the power cord plug, clean the mobile air conditioner according to the steps of 1, 2 and 3, and then pack the machine in a packing box and store it in a cool and dry place.
   
Cooling capacity 1.8kw-2.5kw recommended
more