Sac-250 (refrigerating capacity: 25000w)
 SAC-250-1.jpg        
 SAC-250-2.jpg        
 SAC-250-3.jpg        
Sac-250 (cooling capacity 2500W)
Function introduction
1. Adopt large brand Panasonic large scroll compressor, stable performance and low failure rate
2. Hydrophilic membrane internal thread, all copper tube evaporative condenser
3. Aluminum centrifugal blade, strong wind, uniform airflow, low noise
4. All sheet metal structure, more durable, easy to carry, easy to use, move as you please
5. Energy saving, no installation, plug and play
6. Refrigeration and air supply are selected to meet different requirements
7. It can centralize the air outlet, extend the length of the air outlet pipe, and reduce the temperature in a wide range of posts
8. The internal circulation layout of inlet and outlet air can be carried out to improve the refrigeration efficiency.
9. Integrated design of dehumidification, scientific layout
            SAC-250-1.jpg SAC-250-2.jpg SAC-250-3.jpg        
National 24-hour service hotline: 400-960-2220
Case center    
Product parameters
model SAC-250
Power Supply Three phase 380V / 50Hz
Cooling capacity kw twenty-five
Cooling capacity BTU eighty-five thousand and three hundred
Running current (a) twenty
Power consumption (kw) eleven point two
Water tank capacity (L) /
Air volume (m3 / h) three thousand and three hundred
Automatic wind swing /
Body size (mm) W1330 D950 H1460
Package size (mm) W1410 D1030 H1500
Gross weight (kg) four hundred and three
Net weight (kg) three hundred and thirty
Operating environment 25~45℃
Product features
 pro-detail1.png        
01 Panasonic compressor
Using Panasonic large scroll compressor, hydrophilic aluminum foil heat exchanger and internal thread copper tube, the refrigeration speed is faster, the efficiency is higher, and the energy saving is more silent.
 2018724155123328.jpg        
       
02 Schneider brand
All electrical parts are Schneider brand, which can be used safely.
 20170708091749930.jpg        
03 large space refrigeration
It can be connected with external air duct and air outlet pipe to carry out internal circulation refrigeration for large space, and the cooling effect will be more obvious.
 2018724155926261.jpg     
       
04 simple operation
Humanized control panel, refrigeration, air supply dual choice, simple and convenient operation.
 pd-4.png        
05 high quality motor
Adopt all copper high quality motor, longer service life and lower noise.
 201872415031230.jpg        
06 universal wheel design
All machines are designed with universal wheel, which is convenient to move to any corner of space for use.     
 2018724155956578.jpg    
Application site
 0328153805.png    
Application place of large industrial air conditioner:
1. As a post air conditioner, cooling is carried out for the staff in high temperature working environment.
2. To extend the working life of injection molding machine, communication equipment, etc.
3. Large area places that need ventilation and can not be closed for cooling, such as outdoor exhibition hall, hotel backyard, construction site and other places where it is difficult to install air conditioning in the overall space, so as to provide a cool and comfortable working environment for staff
4. For outdoor sports, such as a golf course
5. Hospital: dust removal and dehumidification in CT department, pharmacy, warehouse, pharmacy department, archives, etc.
5. As an assembly line air conditioner, it can reduce the temperature of multiple posts in the assembly line
6. Cooling the products produced in the equipment to improve the product quality
6. Cooling the products produced in the equipment to improve the product quality
Precautions for use of large industrial air conditioner:
1. When there is adhesion or dust on the surface of mobile air conditioner body, it can be cleaned with soap water to avoid using gasoline, petroleum essence, solvent, etc., to avoid paint dropping or discoloration.
2. The filter screen of the mobile air conditioner should be cleaned regularly (about once every 2 weeks) to maintain the dehumidification and dust removal efficiency and service life of the mobile air conditioner, and to avoid bacterial breeding.
3. If there is a lot of dust and greasy in the use environment, the heat exchanger part of the air conditioner should be cleaned regularly (once every 1-2 weeks). When cleaning, remove the air inlet panel of the mobile air conditioner, dip the toothbrush with soapy water to extend the aluminum plate of the heat exchanger up and down. Remember to prevent the heat exchanger from falling over during cleaning.
4. When the mobile air conditioner is not used for a long time, please pull out the power cord plug, clean the mobile air conditioner according to the steps of 1, 2 and 3, and then pack the machine in a packing box and store it in a cool and dry place.
   
Recommended refrigerating capacity 8kw-25kw