The reason why the air can't come out of the evaporative air conditioner in industrial production
Popularity: 13
Time of publication: September 14, 2020

The reason why the air can't come out of the evaporative air conditioner in industrial production

Industrial production evaporative air conditioner is a portable, no need to open a hole installation, is able to move freely, z-connection type portable high-temperature heatstroke prevention commodity. Industrial evaporative air-conditioner can be used in a variety of scenarios, but sometimes, the industrial production of evaporative air-conditioning opportunities do not come, now, industrial production evaporative air-conditioner cold air machine The reason why there is no wind.

The air inlet of evaporative air conditioner in industrial production is a cycle system, which is completed by internal cooling fan. According to the imported cooling fan, the air conditioner inhales the gas at normal temperature into the equipment, and the gas is divided into cold air and warm air after passing through the filter screen and air conditioner evaporator. The cooling air is discharged by another cooling fan according to the air-conditioning pipe, which can reduce the temperature of human or machine equipment. The warm air is discharged according to the heating pipe.

 The reason why the air can't come out of the evaporative air conditioner in industrial production

The reason why the air can't come out of the evaporative air conditioner in industrial production

Generally speaking, the exhaust air volume reduction is the exhaust air volume of the air-conditioning pipe. The reason is: the filter screen is dirty and blocked. The gas will go through the filter screen, if the filter screen is dirty, it will block the indoor ventilation, resulting in the small exhaust air volume of the air-conditioning pipe or no air. At this time, the filter screen must be disassembled and cleaned. This is the vast majority Industrial air conditioner The key reason why there is no wind.

The second reason is that the internal wind leaves do not turn. It is found that there is no air coming out of the air-conditioning pipe. It is necessary to check whether the centrifugal impeller of the cooling fan is working normally. Sometimes the centrifugal impeller due to unclean things is likely to turn, or because of common faults will not rotate, then it is not easy to air inlet. At this time, we must find technical professional maintenance personnel to carry out maintenance.

The third reason is that the surrounding environment is difficult. Industrial production of evaporative air-conditioner on the application of natural environment has certain provisions, the working temperature can not be too high or too low, all normal applications operating temperature is about 20-41 degrees. And the application of natural environment is best to be able to natural ventilation, there will be warm air out of the area. If it can not meet the above conditions, it is likely to lead to the industrial production of evaporative air conditioner exhaust air volume is small.

Above is the industrial production of evaporative air-conditioner out of the reason, and solutions. Under normal conditions, if the filter screen is maintained on time, it can prevent the air conditioner from blowing out. If there are other problems, it is suggested to find professional personnel to carry out maintenance.